上海美盛自动化设备有限公司
430DPL连续过程氢气和露点分析仪 高达100%的连续分析氢气(H2)和小范围的工艺气体露点流,如热处理,氢/氮和氢冷发电机气氛。
430DPL连续过程氢气和露点分析仪
高达100%的连续分析氢气(H2)和小范围的工艺气体露点流,如热处理,氢/氮和氢冷发电机气氛。
larger image For continuous analysis of up to 99% Hydrogen (H2) and low range dew point in process gas streams such as heat treating, Hydrogen/Nitrogen atmospheres and H2 cooled generators.
Results per Page :
Results 1 - 7 of 7 1
Item #
Enclosure and Mounting Details
Resolution
Output Options
Analyzer Type
Hazardous Area Rating Options
Model 430DPL-N4 Continuous Process Analyzer for Hydrogen and Dew Point, Wall Mounted NEMA4 (IP56) Enclosure Rating ±0.1% H2, ±1° dew point 4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs H2 Analyzer General Purpose, Non-Hazardous Model 430DPL-N4X Continuous Process Analyzer for Hydrogen and Dew Point, Wall Mounted Corrosion-resistant NEMA4X (IP56) Enclosure Rating ±0.1% H2, ±1° dew point 4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs H2 Analyzer General Purpose, Non-Hazardous Model 430DPL-N12 Continuous Process Analyzer for Hydrogen and Dew Point, Wall Mounted NEMA12 (IP52) Enclosure Rating ±0.1% H2, ±1° dew point 4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs H2 Analyzer General Purpose, Non-Hazardous Model 430DPL-RM Continuous Process Analyzer for Hydrogen and Dew Point, 19" (483mm) Rack Mounted, on Sliding Rails ±0.1% H2, ±1° dew point 4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs H2 Analyzer General Purpose, Non-Hazardous Model 430DPL-N7MC Continuous Process Analyzer for Hydrogen and Dew Point, Wall Mounted NEMA7 UL/CSA Explosion-proof with Magnetic Calibration, Meets Class 1 Div 1 Group BCD Rating ±0.1% H2, ±1° dew point 4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs H2 Analyzer Class 1, Div 1, Grp A-D Hazardous Area Rating Model 430DPL-PMN7 Continuous Process Analyzer for Hydrogen and Dew Point, Wall Mounted NEMA7 Sensor Housing with Panel Mounted Control Cabinet (Two Separate Enclosures) ±0.1% H2, ±1° dew point 4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs H2 Analyzer Class 1, Div 1, Grp A-D Hazardous Area Rating Model 430DPL-D2 Continuous Process Analyzer for Hydrogen and Dew Point - 430DPL Model ±0.1% H2, ±1° dew point 4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs H2 Analyzer Class 1, Div 2 Hazardous Area Rating