上海美盛自动化设备有限公司
7900系列工业过程气体分析仪系统 对于任何热处理,如氧气(O2),甲烷(CH4),二氧化碳(CO2),一氧化碳(CO)和氢气(H2),氨气(NH3),和露点(标准大气压的气体连续监测相结合低范围)。也可用于其他工业过程气体。
7900系列工业过程气体分析仪系统
对于任何热处理,如氧气(O2),甲烷(CH4),二氧化碳(CO2),一氧化碳(CO)和氢气(H2),氨气(NH3),和露点(标准大气压的气体连续监测相结合低范围)。也可用于其他工业过程气体。
larger image For continuous monitoring of any combination of heat treat atmosphere gases such as Oxygen (O2), Methane (CH4), Carbon Dioxide (CO2), Carbon Monoxide (CO), Hydrogen (H2), Ammonia (NH3), and Dew Point (standard and low ranges). Also available for other industrial process gases.
Results per Page :
Results 1 - 22 of 22 1
Item #
Enclosure and Mounting Details
Resolution
Response Time (T-90)
Power
Analyzer Type
Hazardous Area Rating Options
Model 7900N4 Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1%, 1 PPM, 1°F (Dew Point) 20-30 seconds to 90% step change 115 VAC, 60 Hz
220 VAC, 50 Hz CO Analyzer General Purpose, Non-Hazardous Model 7901AN4 Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Single Gas Analyzers, Carbon Monoxide only (or as Combustibles = CO x 2), Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1%, 1 PPM, 1°F (Dew Point) 20-30 seconds to 90% step change 115 VAC, 60 Hz
220 VAC, 50 Hz CO Analyzer General Purpose, Non-Hazardous Model 7901BN4 Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Single Gas Analyzers, Hydrogen only, Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1%, 1 PPM, 1°F (Dew Point) 20-30 seconds to 90% step change 115 VAC, 60 Hz
220 VAC, 50 Hz CO Analyzer General Purpose, Non-Hazardous Model 7901CN4 Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Single Gas Analyzers, Combustibles only (as CO + H2, catalytic type with air make-up), Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1%, 1 PPM, 1°F (Dew Point) 20-30 seconds to 90% step change 115 VAC, 60 Hz
220 VAC, 50 Hz CO Analyzer General Purpose, Non-Hazardous Model 7901DN4 Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Single Gas Analyzers, Methane only, Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1%, 1 PPM, 1°F (Dew Point) 20-30 seconds to 90% step change 115 VAC, 60 Hz
220 VAC, 50 Hz CO Analyzer General Purpose, Non-Hazardous Model 7901EN4 Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Single Gas Analyzers, Carbon Dioxide only, Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1%, 1 PPM, 1°F (Dew Point) 20-30 seconds to 90% step change 115 VAC, 60 Hz
220 VAC, 50 Hz CO Analyzer General Purpose, Non-Hazardous Model 7902AN4 Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Double Gas Analyzers, Carbon Monoxide & Carbon Dioxide, Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1%, 1 PPM, 1°F (Dew Point) 20-30 seconds to 90% step change 115 VAC, 60 Hz
220 VAC, 50 Hz CO Analyzer General Purpose, Non-Hazardous Model 7902BN4 Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Double Gas Analyzers, Carbon Monoxide & Hydrogen, Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1%, 1 PPM, 1°F (Dew Point) 20-30 seconds to 90% step change 115 VAC, 60 Hz
220 VAC, 50 Hz CO Analyzer General Purpose, Non-Hazardous Model 7902CN4 Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Double Gas Analyzers, Carbon Monoxide & Oxygen, Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1%, 1 PPM, 1°F (Dew Point) 20-30 seconds to 90% step change 115 VAC, 60 Hz
220 VAC, 50 Hz CO Analyzer General Purpose, Non-Hazardous Model 7902DN4 Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Double Gas Analyzers, Oxygen & Carbon Dioxide, Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1%, 1 PPM, 1°F (Dew Point) 20-30 seconds to 90% step change 115 VAC, 60 Hz
220 VAC, 50 Hz CO Analyzer General Purpose, Non-Hazardous Model 7902EN4 Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Double Gas Analyzers, Oxygen & Hydrogen, Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1%, 1 PPM, 1°F (Dew Point) 20-30 seconds to 90% step change 115 VAC, 60 Hz
220 VAC, 50 Hz CO Analyzer General Purpose, Non-Hazardous Model 7902FN4 Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, Double Gas Analyzers, Oxygen & Methane (Hydrogen & Carbon Dioxide), Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1%, 1 PPM, 1°F (Dew Point) 20-30 seconds to 90% step change 115 VAC, 60 Hz
220 VAC, 50 Hz CO Analyzer General Purpose, Non-Hazardous Model 7903AN4 Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, 3 Gas Analyzers, Carbon Monoxide, Carbon Dioxide, & Methane, Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1%, 1 PPM, 1°F (Dew Point) 20-30 seconds to 90% step change 115 VAC, 60 Hz
220 VAC, 50 Hz CO Analyzer General Purpose, Non-Hazardous Model 7903BN4 Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, 3 Gas Analyzers, Carbon Monoxide, Carbon Dioxide, & Hydrogen, Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1%, 1 PPM, 1°F (Dew Point) 20-30 seconds to 90% step change 115 VAC, 60 Hz
220 VAC, 50 Hz CO Analyzer General Purpose, Non-Hazardous Model 7903CN4 Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, 3 Gas Analyzers, Carbon Monoxide, Carbon Dioxide, & Oxygen, Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1%, 1 PPM, 1°F (Dew Point) 20-30 seconds to 90% step change 115 VAC, 60 Hz
220 VAC, 50 Hz CO Analyzer General Purpose, Non-Hazardous Model 7903DN4 Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, 3 Gas Analyzers, Carbon Monoxide, Methane, & Oxygen, Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1%, 1 PPM, 1°F (Dew Point) 20-30 seconds to 90% step change 115 VAC, 60 Hz
220 VAC, 50 Hz CO Analyzer General Purpose, Non-Hazardous Model 7903EN4 Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, 3 Gas Analyzers, Carbon Monoxide, Hydrogen, & Oxygen, Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1%, 1 PPM, 1°F (Dew Point) 20-30 seconds to 90% step change 115 VAC, 60 Hz
220 VAC, 50 Hz CO Analyzer General Purpose, Non-Hazardous Model 7904AN4 Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, 4 Gas Analyzers, Carbon Monoxide, Carbon Dioxide, Methane, & Oxygen, Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1%, 1 PPM, 1°F (Dew Point) 20-30 seconds to 90% step change 115 VAC, 60 Hz
220 VAC, 50 Hz CO Analyzer General Purpose, Non-Hazardous Model 7904BN4 Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, 4 Gas Analyzers, Carbon Monoxide, Carbon Dioxide, Hydrogen, & Oxygen, Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1%, 1 PPM, 1°F (Dew Point) 20-30 seconds to 90% step change 115 VAC, 60 Hz
220 VAC, 50 Hz CO Analyzer General Purpose, Non-Hazardous Model 7904CN4 Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, 4 Gas Analyzers, Carbon Monoxide, Carbon Dioxide, Methane, & Hydrogen, Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1%, 1 PPM, 1°F (Dew Point) 20-30 seconds to 90% step change 115 VAC, 60 Hz
220 VAC, 50 Hz CO Analyzer General Purpose, Non-Hazardous Model 7904DN4 Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, 4 Gas Analyzers, Carbon Monoxide, Methane, Hydrogen, & Oxygen, Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1%, 1 PPM, 1°F (Dew Point) 20-30 seconds to 90% step change 115 VAC, 60 Hz
220 VAC, 50 Hz CO Analyzer General Purpose, Non-Hazardous Model 7905AN4 Continuous Heat Treat Atmosphere and Industrial Process Gas Analyzer Systems, 5 Gas Analyzer, Carbon Monoxide, Carbon Dioxide, Methane, Hydrogen, & Oxygen, Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1%, 1 PPM, 1°F (Dew Point) 20-30 seconds to 90% step change 115 VAC, 60 Hz
220 VAC, 50 Hz CO Analyzer General Purpose, Non-Hazardous