7200系列连续烟气分析仪 烟气连续分析的任意组合和O2范围,一氧化碳,二氧化碳,二氧化硫,氮氧化物(NO或NO二氧化氮)或可燃物的燃烧过程。
7200系列连续烟气分析仪
烟气连续分析的任意组合和O2范围,一氧化碳,二氧化碳,二氧化硫,氮氧化物(NO或NO二氧化氮)或可燃物的燃烧过程。
Continuous analysis of flue gas for any combination and range of O2, CO, CO2, SO2, NOx (NO or NO + NO2) or combustibles from combustion processes.
larger image
larger image
Results per Page :
Results 1 - 18 of 18 1
Item #
Gases Measured
Method of Detection
Ranges Available
Resolution
7200-1 Oxygen (O2) Electrochemical sensor, paramagnetic sensor or zirconia sensor (depending on desired accuracy and sample composition) 0-5 to 0-25% O2 0.1% on % ranges, 1 PPM on PPM ranges 7200-2 Carbon Monoxide (CO) PPM CO by electrochemical sensor, % CO by NDIR infrared detector 0-100, 0-250, 0-500, 0-2000 by E/C, 0-10,000 PPM CO by infrared detector 0.1% on %, 1 PPM on PPM 7200-3 Carbon Dioxide (CO2) Infrared detector 0-20% CO2 0.1% on %, 1 PPM on PPM 7200-4 Oxides of nitrogen (NOx (as NO)) PPM NO by electrochemical sensor 0-100 to 0-5000 PPM NOx (as NO) 1 PPM 7200-5 Combustibles (LEL, CH4, H2, CO, other) Catalytic sensor (incl. air make up) 0-2, 0-5, 0-10% Combustibles 0.1% 7200-7 SO2 (Sulphur Dioxide) PPM SO2 by electrochemical sensor, % SO2 by infrared detector 0-100 PPM to 0-5% SO2 0.1% on %, 1 PPM on PPM 7200-1-3 Oxygen (O2) and CO2 O2 by electrochemical sensor, paramagnetic sensor or zirconia sensor (depending on desired accuracy and sample composition), CO2 by NDIR infrared detector 0-5 to 0-25% O2, 0-20% CO2 0.1% 7200-1-4 Oxygen (O2) and Oxides of nitrogen (NOx (as NO)) O2 by electrochemical sensor, paramagnetic sensor or zirconia sensor (depending on desired accuracy and sample composition), NOx (as NO) by electrochemical sensor 0-5 to 0-25% O2, 0-20% CO2, 0-100 to 0-5000 PPM NOx (as NO) 0.1% on %, 1 PPM on PPM 7200-1-2-3 Oxygen (O2), Carbon Monoxide (CO), Carbon Dioxide (CO2) % O2 by electrochemical sensor, paramagnetic sensor or zirconia sensor, PPM CO by electrochemical sensor or NDIR infrared detector, % CO by infrared detector, % CO2 by NDIR infrared detector 0-5 to 0-25% O2, 0-100, 0-250, 0-500, 0-2000, 0-10,000 PPM CO, 0-20% CO2 0.1% on %, 1 PPM on PPM 7200-1-2-4 Oxygen (O2), Carbon Monoxide (CO), Oxides of Nitrogen (NOx (as NO)) % O2 by electrochemical sensor, paramagnetic sensor or zirconia sensor, PPM CO by electrochemical sensor or infrared detector, % CO by infrared detector, NOx (as NO) by electrochemical sensor 0-5 to 0-25% O2, 0-100 PPM to 0-99% CO, 0-100 to 0-5000 PPM NOx (as NO) 0.1% on %, 1 PPM on PPM 7200-2-3 Oxygen (O2), Carbon Monoxide (CO), Carbon Dioxide (CO2) PPM CO by electrochemical sensor or NDIR infrared detector, % CO by infrared detector, % CO2 by NDIR infrared detector, % CO2 by NDIR infrared detector 0-5 to 0-25% O2, 0-100, 0-250, 0-500, 0-2000, 0-10,000 PPM CO, 0-20% CO2 0.1% on %, 1 PPM on PPM 7200-2-3-4 Carbon Monoxide (CO), Carbon Dioxide (CO2), Oxides of Nitrogen (NOx (as NO)) % or PPM CO by electrochemical sensor or NDIR infrared detector, % CO2 by NDIR infrared detector, PPM NOx (as NO) by electrochemical sensor 0-100 PPM to 0-99% CO, 0-20% CO2, 0-100 to 0-5000 PPM NOx (as NO) 0.1% on %, 1 PPM on PPM 7200-2-3-7 Carbon Monixide (CO), Carbon Dioxide (CO2), Sulpher Dioxide (SO2) PPM CO by electrochemical sensor, % CO by infrared detector, % CO2 by infrared detector, PPM SO2 by infrared detector 0-100, 0-250, 0-500, 0-2000, 0-10,000 PPM CO, 0-20% CO2, 0-100 PPM to 0-5% SO2 0.1% on %, 1 PPM on PPM 7200-1-2 Oxygen (O2) and CO O2 by electrochemical sensor, paramagnetic sensor or zirconia sensor (depending on desired accuracy and sample composition), PPM CO by electrochemical sensor, % CO by NDIR infrared detector 0-5 to 0-25% O2, 0-100 PPM to 0-99% CO 0.1% on % ranges, 1 PPM on PPM range 7200-3-4 Carbon Dioxide (CO2), Oxides of Nitrogen (NOx (as NO)) % CO2 by NDIR infrared detector, PPM NOx (as NO) by electrochemical sensor 0-20% CO2, 0-100 to 0-5000 PPM NOx (as NO) 0.1% on %, 1 PPM on PPM 7200-1-2-3-5 Oxygen (O2), Carbon Monoxide (CO), Carbon Dioxide (CO2) and Combustibles (Comb) % O2 by electrochemical, paramagnetic or zirconia sensor, PPM CO by electrochemical sensor or infrared detector, % CO by infrared detector, % CO2 by infrared detector, PPM Comb by electrochemical sensor, % Comb by infrared detector 0-5 to 0-25% O2, 0-100, 0-250, 0-500, 0-2000, 0-10,000 PPM CO, 0-20% CO2, 0-2% to 0-10% Combustibles 0.1% on %, 1 PPM on PPM 7200-1-2-4-41 Oxygen (O2), Carbon Monoxide (CO), Nitrogen Oxide (NO) and Nitrogen Dioxide (NO2) % O2 by electrochemical sensor, paramagnetic sensor or zirconia sensor, PPM CO by electrochemical sensor or NDIR infrared detector, % CO by infrared detector, PPM NO or NO2 by electrochemical sensor 0-5 to 0-25% O2, 0-100 PPM to 0-99% CO, 0-100 to 0-5000 PPM NO, 0-100 PPM to 0-800 PPM NO2 0.1% on %, 1 PPM on PPM 7200-1-2-3-4-7 Oxygen (O2), Carbon Monoxide (CO), Carbon Dioxide (CO2), Oxides of Nitrogen (NOx (as NO)), Sulphur Dioxide (SO2) % O2 by electrochemical, paramagnetic or zirconia sensor, PPM CO by electrochemical sensor or infrared detector, % CO and CO 2 by infrared detector, NOx (as NO) and SO2 by electrochemical sensor 0-5 to 0-25% O2, 0-100 PPM to 0-99% CO, 0-20% CO2, 0-100 to 0-5000 PPM NOx (as NO), 0-100 PPM to 0-5% SO2 0.1% on %, 1 PPM on PPM
您感兴趣的产品PRODUCTS YOU ARE INTERESTED IN
仪表网 设计制作,未经允许翻录必究 .
请输入账号
请输入密码
请输验证码
请输入你感兴趣的产品
请简单描述您的需求
请选择省份