上海美盛自动化设备有限公司
600系列便携式多气体分析仪600系列便携式多气体分析仪环境空气监测多达六种气体从周围空气样本同时方便,准确的便携式仪器。在采样泵内置一个绘制样气中的地方它是由六个单独的探测器多达分析。这些检测器输出经过放大和分离,易于阅读的数字仪表显示。对氧的电化学传感器,一氧化碳,二氧化硫,一氧化氮,二氧化氮,氢气,氯气,氨气,硫化氢和有好几年,使用寿命长。
600系列便携式多气体分析仪
600系列便携式多气体分析仪环境空气监测多达六种气体从周围空气样本同时方便,准确的便携式仪器。在采样泵内置一个绘制样气中的地方它是由六个单独的探测器多达分析。这些检测器输出经过放大和分离,易于阅读的数字仪表显示。对氧的电化学传感器,一氧化碳,二氧化硫,一氧化氮,二氧化氮,氢气,氯气,氨气,硫化氢和有好几年,使用寿命长。
The Nova 600 Series Portable Multi-gas Ambient Air analyzers are convenient and accurate portable instruments for monitoring up to six gases simultaneously from ambient air samples. A built in sample pump draws in the sample gas where it is analyzed by up to six separate detectors. These detector outputs are then amplified and displayed on separate, easy-to-read digital meters.
The electrochemical sensors for O2, CO, SO2, NO, NO2, H2, CL2, NH3, and H2S have a long service life of several years. The microprocessor NDIR detector for CO2, the RH sensor and the temperature sensor are all non-consumable.
Specifications · Applications · Features · Options · Calibration · Unique Applications · Models & Configuration Guidelines
Specifications
Method of Detection
O2, CO, SO2, NO, NO2, H2, CL2, NH3 and H2S by electrochemical sensor, % RH by dielectric ceramic sensor, CO2 by infrared sensor, combustibles by catalytic sensor
Ranges Available
0-100 PPM NO
0-99% RH
0-20 PPM H2S
0-20 PPM NH3
0-20.0 PPM CL2
0-20.0 PPM NO2
0-200 PPM CO
0-200 PPM H2
0-25.0% O2
0-50°C Temp.
0-50.0 PPM SO2
0-5000 PPM CO2
Resolution
0.1% on % gas, 1 PPM on PPM gas
Accuracy & Repeatability
±2% of full scale
Drift
Less than 1% of full scale or 1 PPM per 8 hours, whichever is greater, with constant ambient temperature
Response Time (T-90)
Varies with individual sensor but generally under 2 minutes for full reading
Ambient Temperature Range
4 to 49 ºC
40 to 120 ºF
Linearity
±2% of full scale or 1 PPM, whichever is greater
Size & Weight
15" W x 7" H x 12" D @ 14 lbs. (375 x 175 x 305 mm @ 6.4 kg)
Power
115 VAC, 60 Hz for recharging
220 VAC, 50 Hz
Output Options
0-1 VDC
4-20 mA
Alarms
Audible and visual alarms are optionally available as well as low battery and low flow
Gases Measured
0) NH3 - 0-20 PPM
1) O2 - 0-25.0%
2) CO - 0-200 PPM
3) CO2 - 0-5000 PPM
4) LEL Combustibles (not avail. for 5287 Series)
5) H2S - 0-20 PPM
6) SO2 - 0-50 PPM
7) NO - 0-100 PPM
8) NO2 - 0-20 PPM
9) CL2 - 0-20 PPM
Applications
For ambient air or confined space monitoring for up to any six choices of O2, CO2 SO2, NO, NO2, H2, CO, CL2, NH3, H2S, LEL combustibles, temperature, and % RH.
Features
Options
Calibration
Unique Applications
Warm up time is approximately two minutes however NO and NH3 may take up to 2 hours for full stability. The operating humidity range for this series of analyzers is 0-90% RH non-condensing. All Nova analyzers are built using proven technologies and techniques. If this product does not suit your application, please contact Nova. In many cases, we are able to build an analyzer specific to your needs.
Models & Configuration Guidelines
Standard system comes with 'K' series suitcase-style enclosure, built-in sampling pump, flow meter, pre-filter, liquid block, 12 ft (3.6 m) sample hose, rechargeable battery, and recharger.
Arrange Gas numbers in the following order (up to six gases) :
1) O2 - 0-25.0%
2) CO - 0-200 PPM
3) CO2 - 0-5000 PPM
4) LEL - Combustibles (not avail. for 5287 Series)
5) H2S - 0-20 PPM
6) SO2 - 0-50 PPM
7) NO - 0-100 PPM
8) NO2 - 0-20 PPM
9) CL2 - 0-20 PPM
0) NH3 - 0-20 PPM