行业产品

  • 行业产品

上海美盛自动化设备有限公司


LFS-1 Flow Measurement System

返回列表页
参  考  价面议
具体成交价以合同协议为准

产品型号LFS-1 Flow Measurement System

品       牌

厂商性质其他

所  在  地

联系方式:仝先生查看联系方式

更新时间:2023-03-11 10:55:07浏览次数:69次

联系我时,请告知来自 仪表网

经营模式:其他

商铺产品:1883条

所在地区:

联系人:仝先生

产品简介

LFS-1 Flow Measurement SystemOur Products: Laminar Flow Elements (LFE)

详细介绍

LFS-1 Flow Measurement System
Our Products: Laminar Flow Elements (LFE)

LFS-1 Flow Measurement System

Our Products: Laminar Flow Elements (LFE)
SKU: LFS-1
The LFS-1 Flow Measurement System for Meriam LFEs takes advantage of the wide flow turndown and the percent of Reading precision of the LFE, as well as Meriam’s calibration expertise, to provide a superior gas flow measurement solution. The integral flow computer makes real time corrections for changes in differential pressure, static pressure, temperature and relative humidity to provide the most accurate results possible. Calibration coefficients for up to five (5) LFEs can be stored in memory and called up for later use with a push of a button. For control or data transmission purposes, the LFS-1 Flow Measurement System has both analog and digital outputs. 4–20 mA and 0–10 volts analog output options are ideal for control and recording functions. RS-232 and RS-485 digital communications are standard.

Special application requirements can often be accommodated by the LFS. For example, simultaneous flow measurement of two LFEs can be made and the summation of the two flows calculated and displayed. Or, for testing over a wide range for flow, the LFS can be set up to automatically switch from one LFE to an LFE of a different flow capacity as flow rate increases to a predetermined set point.

Meriam’s LFS-1 provides standard system accuracy of ± 1.0% of Reading over a 10:1 flow turndown and ± 1.1% over 20:1 turndown. Calibration of the LFE and LFS-1 as a system makes this possible. Meriam can offer LFS accuracy as low as 0.60% of Reading over a 10:1 flow turndown by using better calibration standards. All LFS packages include complete instrumentation, system calibration and NIST traceable documentation. LFEs and systems cover gas flow ranges from 0.2 SCCM to 15,000 SCFM.

To provide the accurate answers you need in the shortest amount of time, please provide us with the following ordering data:
1. Model number.
2. Flowing gas data;
a. Flow rate in desired units.
b. Base conditions.
i. Pressure
ii. Temperature
c. Flowing conditions
i. Pressure
ii. Temperature
iii. Viscosity at flowing temperature.
d. Differential at maximum flow.
e. Specific gravity, if other than air.
f. Flowing gas, if other than air.
3. Readout instrument.
4. Description of installation configuration.
5. Line size.
6. Line Material.
7. Accuracy required