上海颐品自动化,:

Hawke PL615 Standard Enclosure

Increased Safety Exe / Dual Certified ATEX - IECEx

Materials & Finishes

Glass Reinforced Polyester. Natural Black Finish. Flame Retardant to IEC 92.1 Clause 2.38

General Information

Standard PL615 Enclosures are supplied complete with: Steel Earth Continuity Plate. 1 x M20 tapped entry per face (entries not plugged).

Please Note

Hawke still offer enclosures to customer specifications available from our Box Modifiers.

Technical Data

  1. Increased Safety ex logo II 2 GD Exe IIC Gb, Extb IIIC Db
  2. PL615 Certificate No's
    Baseefa06ATEX0117X and IECEx BAS 06.0028X.
  3. ZPL615 Certificate No's
    Baseefa06ATEX0116U and IECEx BAS 06.0027U.
  4. Suitable for use in:
    Zone 1, Zone 2, Zone 21 and Zone 22.
  5. Construction and Test Standards:
    IEC/EN 60079-0, IEC/EN 60079-7, IEC/EN 60079-31.
  6. Ingress Protection:
    IP66 and IP67 to IEC/EN 60529.
  7. Deluge Protection to:
    DTS01
  8. Operating Temperature Range:
    -60°C to +75°C
  9. Temperature class & ambient:
    T6 40°C, optional T5 with ambients up to 65°C.
TERMINAL DATA
Terminal
Manufacturer
Terminal
Type
Terminal
Quantity
Conductor Size (mm²)Max.
Volts
Max.
Amps
Min.Max.
WeidmullerWDU 2.514
+ 1 Rail Earth
0.52.555016

PL6 & PL7 Series Enclosures Technical Information

To ensure that the maximum temperature as permitted by certification is not exceeded, the dissipated wattage factor formula is used: W = N x F x I² (see enclosure wattage factor).

It is not permitted to fit more than one conductor per side in rail or direct mounted terminals unless using an insulated Bootlace Ferrule.

Linked and mixed terminal arrangements other than those specified in the data tables are available, but the voltage and current figures may be affected to ensure the maximum certified wattage factor is not exceeded. Please contact Hawke Technical Sales for more information.

When connecting a terminal with a conductor that is less than maximum size permitted for that terminal type, the maximum amps per pole must be reduced to suit i.e. an WDU10 (10mm²) terminal fitted with a 4mm² conductor will have the current rating reduced to that of the current rating permitted through the WDU4 (4mm²) terminal.

For Intrinsically Safe Applications, Exe power terminals can be supplied in blue on request. (Note: the enclosure will remain Exe certified).

An earth terminal must be fitted inside the enclosure. (Note: Power terminals may be used as ‘clean earths’).

The enclosure has tapped metric entry threads as standard. Tapered threads are not permitted in plastic enclosures due to risk of stress cracking.

The customer may drill and tap entry holes in the enclosure providing they are in accordance with the relevant code of practice and comply with the certification, contact Hawke Technical Sales for more information.

When mixed entries are required on a face, contact Hawke Technical Sales for more information.

Entries into the enclosure must be via a suitable, approved entry device.

All unused entry holes must be fitted with a stopping plug as listed on the enclosure certificate.

Specification

PL6 Series Certification: ex logo II 2 GD Exe IIC Gb, Extb IIIC, Db.

PL7 Series Certification: ex logo II 2 GD Exe IIC Gb, Extb IIIC, Db.

Zones of Use: Zone 1, Zone 2, Zone 21 & Zone 22.

Temperature Class & Ambients: T6 40°C as standard. Optional T5 with ambients up to 65°C.

Operating Temperature Range: -60°C to +75°C.

PL6 Series Degree of Protection: IP66, IP67 and Deluge proof to DTS01.

PL7 Series Degree of Protection: IP66 and Deluge proof to DTS01.

Material: Glass Reinforced Polyester. Flame Retardant to (IEC92.1 clause 2.38).

Finish: Natural Black.

PL6 Series Impact Resistance: Up to 7Nm.

PL7 Series Impact Resistance: Up to 7Nm.

Weatherproofing: By captive moulded clear silicone gasket.

Certification Label: Stainless Steel or optional certified self adhesive foil.

Lid Fixing Screws: Stainless Steel (complete with nylon retaining washer).

Additional Options: Breather/Drain devices. Internal/external earth stud. Epoxy paint finish for colour coding. EMI/RFI coating for EMC requirements.

Additional Labels: Stainless Steel or laminated plastic (traffolyte) for external use only or optional (certified) self adhesive foil for external and/or internal use.

Earth Continuity

These Enclosures may be fitted with an earth continuity plate in plated mild steel as standard or optional brass when requested by the customer. (Note: A locknut is required on Cable Glands and metal stopping plugs to ensure earth continuity through the plate).

Assembly Instructions

AI 273

Enclosures Dissipated Wattage

ENCLOSURE DISSIPATED WATTAGE
Enclosure TypeTemperature Class
T6 40°C & T5 55°CT6 55°CT5 40°CT6 65°CT5 65°C
PL5111.61.02.20.61.2
PL513 GRP4.12.55.61.53.5
PL520 GRP4.836.61.83.6
PL612 GRP4.12.55.61.53
PL615 GRP6.448.82.44.8
PL620 GRP11.47.115.64.28.5
PL626 GRP11.47.115.64.28.5
PL630 GRP20.81328.67.815.6
PL642 GRP20.81328.67.815.6
PL644 GRP20.81328.67.815.6
PL712 GRP3.352.144.61.22.4
PL722 GRP5.313.327.31.93.9
Size 1 Stainless Steel13.958.719.15.210.4
Size 2 Stainless Steel18.1511.324.96.813.6
Size 2L Stainless Steel18.1511.324.96.813.6
Size 3 Stainless Steel23.714.832.58.817.7
Size 4 Stainless Steel29.9518.741.111.222.4
Size 4L Stainless Steel29.9518.741.111.222.4
Size 5 Stainless Steel32.8520.545.112.324.6
Size 6 Stainless Steel4025551530
Size 7 Stainless Steel5223.571.519.539
Size 8 Stainless Steel6540.689.324.348.7
Size 9 Stainless Steel79.3549.5109.129.759.5
EJB14.742.966.511.7783.55
EJB26.644.159.132.494.98

Dissipated Wattage Factor

The Dissipated Wattage Factor of the enclosures has been established by test to ensure that the maximum temperature as permitted by temperature certification is not exceeded. When terminal quantities greater than those at maximum amps are required (up to maximum physical quantity only) then the current shall be reduced accordingly to remain within the Dissipated Wattage Factor of the enclosure.

Combined Terminal Resistance Factor

This factor is used to determine the number of terminals that can be accommodated within the enclosure without exceeding the Wattage Factor. The Combined Terminal Resistance Factor is the sum of the individual terminal resistance's and the resistance of the cable core equal in length to the enclosure maximum diagonal. (Core Resistance is taken from BS6360). Combined terminal resistance factor.

Wattage to be Dissipated = N x F x I²

N = Number of Terminals. F = Combined Terminal Resistance Factor. I = Maximum Current.

e.g. Number of terminals in a PL630 Enclosure at 20.8 Watts - 10 x 'WDU 2.5' (1=17A), 2 x 'WDU 6' (1=29A), (10 x 0.003035 x 17 ² = 8.77 watts) + (2 x 0.001404 x 29 ²) = 2.36 watts). Total Watts = 8.77 + 2.36 = 11.13 watts.

Therefore this terminal combination is acceptable as the wattage is less than that of the PL630 maximum watts of 20.8 watts.

Note - If a smaller than maximum permitted conductor is fitted into a power terminal, then the smaller conductor resistance must be used when calculating the combined terminal resistance.

Transposed Formula

enclosures dissipated wattage equation
Download Data Sheet

Combined Terminal Resistance

PL Series GRP Enclosures

Combined Terminal Resistance (Ω)
Terminal TypeEnclosure Type
PL511PL513PL520PL612PL615PL620PL626PL630PL642PL644PL712PL722
WDU 2.5N0.0014900.0016860.0020570.0013010.0016570.0021380.0023980.0030650.0035610.0042720.0014120.002035
WDU 2.50.0014600.0016560.0026890.0012710.0016270.0021080.0023680.0030350.0035310.0042420.0013820.002005
WDU 40.0010130.0011350.0013660.0008950.0011170.0014160.0015780.0019930.0023020.0027440.0009650.001352
WDU 60.0007490.0008320.0009850.0006710.0008190.0010190.0011270.0014040.0016110.0019060.0007170.000976
WDU 10-0.0005280.0006190.0004320.0005200.0006390.0007030.0008680.0009910.0011660.0004600.000614
WDU 16-0.0003560.000413-0.0003510.0004260.0004660.0005700.0006470.000757--
WDU 35-0.0001940.000220--0.0002260.0002440.0002910.0003260.000377--
WDU 50N-----0.000164-0.0002113-0.000202--
WDU 70N-----0.000124-0.0001580.000176---
UT 2.50.001113-----------
UT 40.000729-----------
UT 60.000479-----------

Download Data Sheet

PL Series Enclosures Maximum Physical Quantity Of Terminals

W Series And Direct Mounted Terminals

MAXIMUM PHYSICAL QUANTITY OF TERMINALS
Terminal TypeEnclosure Type
PL511PL513PL520PL612PL615PL620PL626PL630PL642PL644PL712PL722
1 Diagonal Rail2 Vertical Rails
WDU 2.5N10183012 + 1 Earth
(1 central or offset entry only)
N/AN/A38 + 1 EarthN/AN/A11516412 + 1 Earth
(1 central entry only)
N/A
WDU 2.59183010 + 1 Earth
(1 offset entry only)
14 + 1 Earth24 + 1 Earth38 + 1 Earth50 + 1 Earth76 + 2 Earths
(38 + 1 earth per rail)
11516410 + 1 Earth
(1 central entry only)
35 + 1 Earth
(No entries on faces B & D)
WDU 4815258 + 1 Earth
(1 offset entry only)
12 + 1 Earth20 + 1 Earth32 + 1 Earth42 + 1 Earth64 + 2 Earths
(32 + 1 earth per rail)
971378 + 1 Earth
(1 central entry only)
29 + 1 Earth
(No entries on faces B & D)
WDU 6611207 + 1 Earth
(1 offset entry only)
9 + 1 Earth15 + 1 Earth24 + 1 Earth30 + 1 Earth48 + 2 Earths
(24 + 1 earth per rail)
731047 + 1 Earth
(1 central entry only)
22 + 1 Earth
(No entries on faces B & D)
WDU 10N/A9155 + 1 Earth
(1 offset entry only)
7 + 1 Earth12 + 1 Earth19 + 1 Earth25 + 1 Earth36 + 2 Earths
(18 + 1 earth per rail)
59835 + 1 Earth
(1central entry only)
17 + 1 Earth
(No entries on faces B & D)
WDU 16N/A712N/A6 + 1 Earth
(1 offset entry only)
9 + 1 Earth16 + 1 Earth20 + 1 Earth30 + 2 Earths
(15 + 1 earth per rail)
4968N/AN/A
WDU 35N/AN/A9N/AN/A6 + 1 Earth12 + 1 Earth15 + 1 Earth22 + 2 Earths
(11 + 1 earth per rail)
1750N/AN/A
WDU50NN/AN/AN/AN/AN/A5 + 1 EarthN/A11 + 1 EarthN/AN/AN/AN/AN/A
WDU 70NN/AN/AN/AN/AN/A4 + 1 EarthN/A11 + 1 Earth
(Conductor termination
difficult - Advise 9 + 1 Earth)
N/A1515N/AN/A
UT 2.59N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/A
UT 48N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/A
UT 66N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/A
BK6N/AN/AN/A1N/AN/AN/AN/AN/AN/AN/A1N/A
MK6/6N/AN/AN/A1N/AN/AN/AN/AN/AN/AN/A1N/A
HTB/6N/AN/AN/A112N/AN/AN/AN/AN/A1N/A

Notes:

Earths (PL511, PL513, PL520, PL612 and PL712) The rail earths may be replaced by a pillar earth, but a bracket shall be fitted at the end of the terminal stack in it's place.

Entries (PL511, PL513, PL520, PL612, PL615 ,PL626, PL712 and PL722) Where the quantity of entries has been restricted, this is due to limited space. If multiple entries are required, then the quantity of power terminals shall be reduced accordingly. PL712 - It may be possible for some maximum terminal assemblies to use two M20/O entry positions.

Rails (PL513, PL520, PL612, PL615, PL620 and PL712) 1 Diagonal rail.
PL511, PL626 and PL722: 1 Horizontal rail.
PL630: 1 diagonal or 2 vertical rails.

Enclosures Dissipated Wattage

ENCLOSURE DISSIPATED WATTAGE
Enclosure TypeTemperature Class
T6 40°C & T5 55°CT6 55°CT5 40°CT6 65°CT5 65°C
PL5111.61.02.20.61.2
PL513 GRP4.12.55.61.53.5
PL520 GRP4.836.61.83.6
PL612 GRP4.12.55.61.53
PL615 GRP6.448.82.44.8
PL620 GRP11.47.115.64.28.5
PL626 GRP11.47.115.64.28.5
PL630 GRP20.81328.67.815.6
PL642 GRP20.81328.67.815.6
PL644 GRP20.81328.67.815.6
PL712 GRP3.352.144.61.22.4
PL722 GRP5.313.327.31.93.9
Size 1 Stainless Steel13.958.719.15.210.4
Size 2 Stainless Steel18.1511.324.96.813.6
Size 2L Stainless Steel18.1511.324.96.813.6
Size 3 Stainless Steel23.714.832.58.817.7
Size 4 Stainless Steel29.9518.741.111.222.4
Size 4L Stainless Steel29.9518.741.111.222.4
Size 5 Stainless Steel32.8520.545.112.324.6
Size 6 Stainless Steel4025551530
Size 7 Stainless Steel5223.571.519.539
Size 8 Stainless Steel6540.689.324.348.7
Size 9 Stainless Steel79.3549.5109.129.759.5
EJB14.742.966.511.7783.55
EJB26.644.159.132.494.98

Dissipated Wattage Factor

The Dissipated Wattage Factor of the enclosures has been established by test to ensure that the maximum temperature as permitted by temperature certification is not exceeded. When terminal quantities greater than those at maximum amps are required (up to maximum physical quantity only) then the current shall be reduced accordingly to remain within the Dissipated Wattage Factor of the enclosure.

Combined Terminal Resistance Factor

This factor is used to determine the number of terminals that can be accommodated within the enclosure without exceeding the Wattage Factor. The Combined Terminal Resistance Factor is the sum of the individual terminal resistance's and the resistance of the cable core equal in length to the enclosure maximum diagonal. (Core Resistance is taken from BS6360). Combined terminal resistance factor.

Wattage to be Dissipated = N x F x I²

N = Number of Terminals. F = Combined Terminal Resistance Factor. I = Maximum Current.

e.g. Number of terminals in a PL630 Enclosure at 20.8 Watts - 10 x 'WDU 2.5' (1=17A), 2 x 'WDU 6' (1=29A), (10 x 0.003035 x 17 ² = 8.77 watts) + (2 x 0.001404 x 29 ²) = 2.36 watts). Total Watts = 8.77 + 2.36 = 11.13 watts.

Therefore this terminal combination is acceptable as the wattage is less than that of the PL630 maximum watts of 20.8 watts.

Note - If a smaller than maximum permitted conductor is fitted into a power terminal, then the smaller conductor resistance must be used when calculating the combined terminal resistance.

Transposed Formula

enclosures dissipated wattage equation

Combined Terminal Resistance

PL Series GRP Enclosures

Combined Terminal Resistance (Ω)
Terminal TypeEnclosure Type
PL511PL513PL520PL612PL615PL620PL626PL630PL642PL644PL712PL722
WDU 2.5N0.0014900.0016860.0020570.0013010.0016570.0021380.0023980.0030650.0035610.0042720.0014120.002035
WDU 2.50.0014600.0016560.0026890.0012710.0016270.0021080.0023680.0030350.0035310.0042420.0013820.002005
WDU 40.0010130.0011350.0013660.0008950.0011170.0014160.0015780.0019930.0023020.0027440.0009650.001352
WDU 60.0007490.0008320.0009850.0006710.0008190.0010190.0011270.0014040.0016110.0019060.0007170.000976
WDU 10-0.0005280.0006190.0004320.0005200.0006390.0007030.0008680.0009910.0011660.0004600.000614
WDU 16-0.0003560.000413-0.0003510.0004260.0004660.0005700.0006470.000757--
WDU 35-0.0001940.000220--0.0002260.0002440.0002910.0003260.000377--
WDU 50N-----0.000164-0.0002113-0.000202--
WDU 70N-----0.000124-0.0001580.000176---
UT 2.50.001113-----------
UT 40.000729-----------
UT 60.000479-----------

PL Series Enclosures Maximum Physical Quantity Of Terminals

W Series And Direct Mounted Terminals

MAXIMUM PHYSICAL QUANTITY OF TERMINALS
Terminal TypeEnclosure Type
PL511PL513PL520PL612PL615PL620PL626PL630PL642PL644PL712PL722
1 Diagonal Rail2 Vertical Rails
WDU 2.5N10183012 + 1 Earth
(1 central or offset entry only)
N/AN/A38 + 1 EarthN/AN/A11516412 + 1 Earth
(1 central entry only)
N/A
WDU 2.59183010 + 1 Earth
(1 offset entry only)
14 + 1 Earth24 + 1 Earth38 + 1 Earth50 + 1 Earth76 + 2 Earths
(38 + 1 earth per rail)
11516410 + 1 Earth
(1 central entry only)
35 + 1 Earth
(No entries on faces B & D)
WDU 4815258 + 1 Earth
(1 offset entry only)
12 + 1 Earth20 + 1 Earth32 + 1 Earth42 + 1 Earth64 + 2 Earths
(32 + 1 earth per rail)
971378 + 1 Earth
(1 central entry only)
29 + 1 Earth
(No entries on faces B & D)
WDU 6611207 + 1 Earth
(1 offset entry only)
9 + 1 Earth15 + 1 Earth24 + 1 Earth30 + 1 Earth48 + 2 Earths
(24 + 1 earth per rail)
731047 + 1 Earth
(1 central entry only)
22 + 1 Earth
(No entries on faces B & D)
WDU 10N/A9155 + 1 Earth
(1 offset entry only)
7 + 1 Earth12 + 1 Earth19 + 1 Earth25 + 1 Earth36 + 2 Earths
(18 + 1 earth per rail)
59835 + 1 Earth
(1central entry only)
17 + 1 Earth
(No entries on faces B & D)
WDU 16N/A712N/A6 + 1 Earth
(1 offset entry only)
9 + 1 Earth16 + 1 Earth20 + 1 Earth30 + 2 Earths
(15 + 1 earth per rail)
4968N/AN/A
WDU 35N/AN/A9N/AN/A6 + 1 Earth12 + 1 Earth15 + 1 Earth22 + 2 Earths
(11 + 1 earth per rail)
1750N/AN/A
WDU50NN/AN/AN/AN/AN/A5 + 1 EarthN/A11 + 1 EarthN/AN/AN/AN/AN/A
WDU 70NN/AN/AN/AN/AN/A4 + 1 EarthN/A11 + 1 Earth
(Conductor termination
difficult - Advise 9 + 1 Earth)
N/A1515N/AN/A
UT 2.59N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/A
UT 48N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/A
UT 66N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/A
BK6N/AN/AN/A1N/AN/AN/AN/AN/AN/AN/A1N/A
MK6/6N/AN/AN/A1N/AN/AN/AN/AN/AN/AN/A1N/A
HTB/6N/AN/AN/A112N/AN/AN/AN/AN/A1N/A

Notes:

Earths (PL511, PL513, PL520, PL612 and PL712) The rail earths may be replaced by a pillar earth, but a bracket shall be fitted at the end of the terminal stack in it's place.

Entries (PL511, PL513, PL520, PL612, PL615 ,PL626, PL712 and PL722) Where the quantity of entries has been restricted, this is due to limited space. If multiple entries are required, then the quantity of power terminals shall be reduced accordingly. PL712 - It may be possible for some maximum terminal assemblies to use two M20/O entry positions.

Rails (PL513, PL520, PL612, PL615, PL620 and PL712) 1 Diagonal rail.
PL511, PL626 and PL722: 1 Horizontal rail.
PL630: 1 diagonal or 2 vertical rails.

 

 