Model/ Parameter | AG-I20 |
Item Name | Test Probe with Force |
Standard | IEC60884-1 figure 9. |
Application | The AG-I20 test probe with 20N force is used to test whether the live parts inside can be touched. |
Test Sample | Socket. |
Feature | Nylon handle + probe. |
The probe part | 3+0.03 0×1+0.015 0 ×80±0.5 |
The diameter of the round | R0.2±0.05 |
Force | With 20N force |
Standard | IEC60884-1 figure 9 |