本公司位于山东省青岛市市北区,常年对外销售CEMS烟气监测备品备件,例如SO2,NO气体分析仪、采样探头、皮托管、温压流一体机、冷凝器、烟尘仪,伴热管、蠕动泵、过滤器等等。

点击展示更多内容
SP2000-H/DILBasedonprobeSP2000H/
取样探头 产品详情

SP2000-H/DIL

Based on probe SP2000H/....

Electrically heated up to 180°C

External critical orifice is heated

Including a dilution gas pre-heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.


SP2300-H/DIL

Based on probe SP2300H/....

Electrically heated up to 180°C

External critical orifice is heated

Including a dilution gas pre-heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

Material: PTFE, FPM, ceramic

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2300H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.


SP2000-H320/DIL

Based on probe SP2000H/....

Electrically heated up to 320°C

External critical orifice is heated

Including a dilution gas pre-heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.


SP2000-H/DIL-VA

Based on probe SP2000H/....

Electrically heated up to 180°C

External critical orifice is heated

Including a dilution gas pre- heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

With integrated ball valve at the probe inlet

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials. With the integrated ball valve it is possible to shut off the probe from the process for example to change the filter element in case of toxic sample gas.


SP2000-H/DIL-B

Based on probe SP2000H/....

Electrically heated up to 180°C

External critical orifice is heated

Including a dilution gas pre- heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

With bypass injector to minimize the response time

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.The additional bypass injector minimizes the response time.


SP2000-H320/DIL-B

Based on probe SP2000H/....

Electrically heated up to 320°C

External critical orifice is heated

Including a dilution gas pre- heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

With bypass injector to minimize the response time

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.The additional bypass injector minimizes the response time.


SP2000-H/DIL-BR

Based on probe SP2000H/....

Electrically heated up to 180°C

External critical orifice is heated

Including a dilution gas pre- heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

With bypass injector to minimize the response time and integrated gas recirculation

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.The additional bypass injector minimizes the response time and the integrated gas recirculation allows to remove the sample gas back into the process.

SP2000-H320/DIL-BR

Based on probe SP2000H/....

Electrically heated up to 320°C

External critical orifice is heated

Including a dilution gas pre- heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

With bypass injector to minimize the response time and integrated gas recirculation

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.The additional bypass injector minimizes the response time and the integrated gas recirculation allows to remove the sample gas back into the process.

SP2000-H/DIL-VA-B

Based on probe SP2000H/....

Electrically heated up to 180°C

External critical orifice is heated

Including a dilution gas pre- heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

With integrated ball valve at the probe inlet and bypass injector to minimize the response time

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.With the integrated ball valve it is possible to shut off the probe from the process for example to change the filter element in case of toxic sample gas and the additional bypass injector minimizes the response time.


SP2000-H/DIL-VA-BV

Based on probe SP2000H/....

Electrically heated up to 180°C

External critical orifice is heated

Including a dilution gas pre-heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

With heated hand-operated ball valve at the sample inlet and bypass connection with needle valve in order to minimize the response time

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials. With the integrated ball valve it is possible to shut off the probe from the process for example to change the filter element in case of toxic sample gas and the additional bypass injector with needle valve minimizes the response time.


SP2006-H/DIL-B/2x/F

Based on probe SP2000-H/...

Electrically heated up to 180 °C or 280 °C

NEMA 4, FRP housing

External heated critical orifice with additional safety filter

Including a dilution gas pre-heater

No dew point problems

Dilution ratios from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Changing of dilution and bypass block without any tools within a few minutes

No disconnection of any tubes or hoses for changing of dilution or bypass block

Easy operation and maintenance

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2006H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials. The additional bypass injector minimizes the response time.


SP2006-H/DIL-BR/2x/F

Based on probe SP2000-H/...

Electrically heated up to 180 °C or 280 °C

NEMA 4, FRP housing

External heated critical orifice with additional safety filter

Including a dilution gas pre-heater

No dew point problems

Dilution ratios from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Changing of dilution and bypass block without any tools within a few minutes

No disconnection of any tubes or hoses for changing of dilution or bypass block

Easy operation and maintenance

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2006H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials. The additional bypass injector minimizes the response time.


SP2006-H/DIL/2x/F

Based on probe SP2000-H/...

Electrically heated up to 180 °C or 280 °C

NEMA 4, FRP housing

External heated critical orifice with additional safety filter

Including a dilution gas pre-heater

No dew point problems

Dilution ratios from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Changing of dilution and bypass block without any tools within a few minutes

No disconnection of any tubes or hoses for changing of dilution or bypass block

Easy operation and maintenance

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2006H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials. The additional bypass injector minimizes the response time.

热门产品
产品名称参考价地区公司名称更新时间 
荧光定量真菌毒素检测仪 优云谱 粮食安全快速检测仪 YP-L02 面议 潍坊市 山东优云谱光电科技有限公司 2025-05-01 在线询价
艾德克斯ITECH 微功耗量测以及材料研究精密源表 IT2805 200V1.5A20W 面议 深圳市 深圳市赛仪欧电子有限公司 2025-03-04 在线询价
测长机计量仪器 ¥424000 深圳市 深圳市中图仪器股份有限公司 2025-05-14 在线询价
罗卓尼克USB接口水活性快速测量探头 面议 无锡市 无锡徽科特测控技术有限公司 2025-03-10 在线询价
激光功率测量系统 LPMS 面议 上海倍蓝光电科技有限公司 2025-04-08 在线询价
水分活度测量仪厂商 面议 常州市 常州金坛泰纳仪器厂 2025-03-10 在线询价
免责申明

所展示的信息由会员自行提供,内容的真实性、准确性和合法性由发布会员负责,仪表网对此不承担任何责任。仪表网不涉及用户间因交易而产生的法律关系及法律纠纷,纠纷由您自行协商解决

友情提醒 :本网站仅作为用户寻找交易对象,就货物和服务的交易进行协商,以及获取各类与贸易相关的服务信息的平台。为避免产生购买风险,建议您在购买相关产品前务必确认供应商资质及产品质量。过低的价格、夸张的描述、私人银行账户等都有可能是虚假信息,请采购商谨慎对待,谨防欺诈,对于任何付款行为请您慎重抉择!如您遇到欺诈等不诚信行为,请您立即与仪表网联系,如查证属实,仪表网会对该企业商铺做注销处理,但仪表网不对您因此造成的损失承担责任!

关于我们|网站导航|本站服务|会员服务|网站建设|特色服务|旗下网站|友情链接|在线投诉|兴旺通|供应信息

仪表网-仪器仪表行业“互联网+”服务平台

Copyright ybzhan.cn All Rights Reserved法律顾问:浙江天册律师事务所 贾熙明律师ICP备案号:浙B2-20100369-24

客服热线:0571-87756399,87759942加盟热线:0571-87756399展会合作:0571-87759945客服邮箱:873582202@qq.com 投稿邮箱:ybzhan@qq.com

网站客服:服务咨询:对外合作:仪表采购群: 仪表技术群:

版权所有©浙江兴旺宝明通网络有限公司


提示

×