*HL55T(0.2级)电流互感器
上海源倾电气有限公司主营产品:直流电阻测试仪,蓄电池组负载测试仪,回路电阻测试仪,微机继电保护测试仪,接地电阻测试仪,高压无线核相仪,*HL55T(0.2级)电流互感器,高压试验变压器,直流单双臂电桥,直流高压发生器,管状电加热器,绝缘油介电强度测试仪,手表式近电报警器,氧化锌 避雷器测试仪,绝缘电阻测试仪,高压兆欧表,高压绝缘垫,短路接地线等等
型号 | 主要技术指标 | |||
标准度 | 功率 | 额定 | 初级电流(A) | |
HL1 | 0.2 | 0.8 | 5 | 固定:15,50 穿心:100-150-200-300-600 |
HL1A | 0.1 | 0.8-1 | 10 | 固定:15,50 穿心:100-150-200-300-600 |
HL2 | 0.2 | 0.8 | 10 | 100-150-200-250-300-400-500-600-750-800-1000-1200-1500-2000 |
HL3 | 0.2 | 0.8 | 10 | 0.5-1-2-5-10-20-50 |
HL5-1 | 0.1 | 0.8或1 | 5 | 5-6-7.5-10-15-20-25-30-40-50-60-75-100-150-200-250-300-500-600-750-800-1000 |
HL16 | 0.1 | 0.8-1 | 10 | 300-400-500-600-750-1000-1500-2000-3000-4000 |
HL18 | 0.1 | 0.8-1 | 5 | 5-6-7.5-10-15-20-25-30-40-50-60-75-100-150-200-250-300-400-500 |
HL19 | 0.1 | 0.8-1 | 5 | 500-600-750-800-1000-2000-3000-4000-5000 |
HL23 | 0.1 | 0.8或1 | 5 | 0.5-1-2.5-5-10-25-50-100-150-200-250-300-400-500-600-700-750-1000-1200-1400-1500-1800-2000 |
HL23-1 | 0.2 | 0.8 | 10 | 0.5-1-2.5-5-10-25-50-100-150-200-250-300-400-500-600-700-750-1000-1200-1400-1500-1800-2000 |
HL23-2 | 5-10-25-50-100-150-200-250-300-400-500-600-700-750-1000-1200-1400-1500-1800-2000 | |||
HL23-3 | 15-30-50-75-150-200-300-400-600-700-800-1200-1400-1600 | |||
HL23-4 | 10-25-50-100-150-200-250-300-400-500-600-700-750-1000-1200-1400 | |||
HL23-5 | 0.25-0.5-1-2.5-5-10-25-50-100-150-200-250-300-400-500-600-700-750-900-1000-1200-1400-1500-1800-2000 | |||
HL23-9 | 0.1 | 0.8 | 10 | 0.1-0.25-0.5-1-2.5-5-10-25-50-100 |
HL24-1 | 0.2 | 0.8 | 10 | 10-25-50-100-150-200-300-600 |
HL24-2 | 10-25-50-100-200-250-500-1000 | |||
HL24-1A | 0.1 | 10-25-50-100-150-200-300-600 | ||
HL24-2A | 10-25-50-100-200-250-500-1000 | |||
0.5-1-2-2.5-5-10-15-20-25-30-50-75-100 | ||||
HL32-1 | 0.1 | 0.8-1 | 5 | |
HL32-2 | 10 | 0.5-2-2.5-5-10-15-20-25-30-50-75-100 | ||
HL34 | 0.02 | 1 | 5 | 5-7.5-10-15-20-25-30-40-50-60-75-100-150-200-250-300 |
HL35 | 0.1 | 1 | 5 | 0.5-0.75-1-1.5-2-2.5-3-4-5-7.5-10-15-20-25-30-40-50-60-75-100-150-200-250-300 |
HL35-1 | 0.1 | 0.8-1 | 10 | 0.5-0.75-1-1.5-2-2.5-3-4-5-7.5-10-15-20-25-30-40-50-75-100 |
HL35-2 | 5-7.5-10-15-20-25-30-40-50-60-75-80-100-120-150-200-250-300-400-500-600-750-800-1000-1500-2500-3000-4000-5000 | |||
HL35-4 | 15-20-25-30-40-50-60-80-100-150-200-250-300-400-500-600 | |||
HL36 | 0.2 | 0.8 | 10 | 100-150-200-250-300-400-500-600-750-800-1000-1200-1500-2000 |
HL36A | 0.1 | 0.8 | 10 | 100-150-200-250-300-400-500-600-750-800-1000-1200-1500-2000 |
HL36-1 | 0.2 | 0.8 | 5 | 100-150-200-250-300-400-500-600-750-800-1000-1200-1500-2000(二次为1A) |
HL36-1A | 0.1 | 0.8 | 5 | 100-150-200-250-300-400-500-600-750-800-1000-1200-1500-2000(二次为1A) |
HL37-4 | 0.2 | 0.8-1 | 10 | 15-20-25-30-40-50-60-80-100-150-200-250-300-400-500-600 |
HL41 | 0.1 | 0.8-1 | 5 | 0.1-0.15-0.2-0.25-0.3-0.4-0.5-0.6-0.75-1-1.5-2-2.5-3-4-5-6-7.5-10-15-20-25-30-40-50-60-75-80-100 |
HL42 | 0.2 | 0.8-1 | 5 | 0.1-0.15-0.2-0.25-0.3-0.4-0.5-0.6-0.75-1-1.5-2-2.5-3-4-5-7.5-10-15-20-25-30-40-50-75-80-100 |
HL50A | 0.05 | 1 | 10 | 5-7.5-10-15-20-25-30-40-50-60-75-80-100-120-150-200-250-300-400-500-600-750-800-1000-1200-1500-2000-2500-3000-4000-5000-6000-7500-8000-10000 |
HL55 | 0.2 | 0.8-1 | 5 | 端子:10-20-50 穿芯:100-150-200-300-600 |
HL55A | 0.1 | 0.8-1 | 5 | 端子:10-20-50 穿芯:100-150-200-300-600 |
HL55-1 | 0.2 | 0.8-1 | 5 | 端子:10-20-50 穿芯:100-150-200-300-600 (二次为1A) |
HL55-1A | 0.1 | 0.8-1 | 5 | 端子:10-20-50 穿芯:100-150-200-300-600 (二次为1A) |
HL55T | 0.2 | 0.2 | 5 | 端子:5-20-100 穿芯:200-300-600 |
主要技术要求:
2.1 额定容量:额定二次电流通过二次额定负荷时所消耗的视在功率。额定容量可以用视在功率V.A表示,也可以用二次额定负荷阻抗Ω表示。
2.2 一次额定电流:允许通过电流互感器一次绕组的用电负荷电流。用于电力系统的电流互感器一次额定电流为5~25000A,用于试验设备的精密电流互感器为 0.1~50000A。电流互感器可在一次额定电流下*运行,负荷电流超过额定电流值时叫做过负荷,电流互感器*过负荷运行,会烧坏绕组或减少使用寿命。
2.3 二次额定电流:允许通过电流互感器二次绕组的一次感应电流。
2.4 额定电流比(变比):一次额定电流与二次额定电流之比。
2.5 额定电压:一次绕组*对地能够承受的大电压(有效值以kV为单位),应不低于所接线路的额定相电压。电流互感器的额定电压分为0.5,3,6,10,35,110,220,330,500kV等几种电压等级。
2.6 10%倍数:在的二次负荷和任意功率因数下,电流互感器的电流误差为-10%时,一次电流对其额定值的倍数。10%倍数是与继电保护有关的技术指标。
2.7 准确度等级:表示互感器本身误差(比差和角差)的等级。电流互感器的准确度等级分为0.001~1多种级别,与原来相比准确度提高很大。用于发电厂、变电站、用电单位配电控制盘上的电气仪表一般采用0.5级或0.2级;用于设备、线路的继电保护一般不低于1级;用于电能计量时,视被测负荷容量或用电量多少依据规程要求来选择(见*讲)。
2.8 比差:互感器的误差包括比差和角差两部分。比值误差简称比差,一般用符号f表示,它等于实际的二次电流与折算到二次侧的一次电流的差值,与折算到二次侧的一次电流的比值,以百分数表示。
2.9 角差:相角误差简称角差,一般用符号δ表示,它是旋转180°后的二次电流向量与一次电流向量之间的相位差。规定二次电流向量超前于一次电流向量δ为正值,反之为负值,用分(’)为计算单位。