您好, 欢迎来到仪表网

| 注册| 产品展厅| 收藏该商铺

021-60645668

products

目录:珀金埃尔默企业管理(上海)有限公司>> WGA-PEI TYPE A PS 500 MG

WGA-PEI TYPE A PS 500 MG
  • WGA-PEI TYPE A PS 500 MG
参考价 面议
具体成交价以合同协议为准
参考价 面议
具体成交价以合同协议为准
  • 品牌
  • 型号
  • 厂商性质 生产商
  • 所在地
属性

>

更新时间:2023-10-20 09:48:11浏览次数:68评价

联系我们时请说明是仪表网上看到的信息,谢谢!

同类优质产品

更多产品
WGA-coated SPA beads, for capturing cell membranes in proximity-based scintillation assays.

The treatment of WGA SPA beads with positively charged polyethyleneimine (PEI) blocks potential non-specific binding sites on the SPA bead surface. There are two SPA bead types available with PEI treatment. The WGA-PEI type A SPA beads are treated with PEI prior to the coupling of WGA to the SPA bead. The WGA PEI type B SPA beads are treated with PEI after the WGA coupling stage. The WGA-PEI type A and type B SPA beads exhibit different characteristics with regard to the non-specific binding of radiolabelled ligand directly to the SPA bead. Therefore, both bead types should be evaluated when deciding which SPA bead to use and both are included in the Select-a-Bead Kit. The binding capacity of both bead types for cell membrane protein remains 10–30 μg membrane protein per milligram of SPA bead.

SPA Imaging beads are microspheres containing scintillant which emit light in the red region of the visible spectrum. As a result, these beads are ideally suited to use with a CCD imager, such as PerkinElmer's Viewlux™ CCD Imager.

Two types of core SPA Imaging bead are available - yttrium oxide (YOx) and Polystyrene (PS). A number of biological coatings also exist for each core bead type to enable receptor binding, enzyme, molecular interaction and radioimmunoassays to be investigated.

Scintillation proximity assay (SPA) is a homogeneous and versatile technology for the rapid and sensitive assay of a wide range of biological processes, including applications using enzyme and receptor targets, radioimmunoassays, and molecular interactions. When 3H, 14C, 33P, and 125I radioisotopes decay, they release β-particles (or Auger electrons, in the case of 125I). The distance these particles travel through an aqueous solution is dependent on the energy of the particle. If a radioactive molecule is held in close enough proximity to a SPA Scintillation Bead or a SPA Imaging Bead, the decay particles stimulate the scintillant within the bead to emit light, which is then detected in a PMT-based scintillation counter or on a CCD-based imager, respectively. However, if the radioactive molecule does not associate with the SPA bead, the decay particles will not have sufficient energy to reach the bead and no light will be emitted. This discrimination of binding by proximity means that no physical separation of bound and free radiochemical is required.

规格

自动化兼容 Yes
珠型或核心珠型 Polystyrene (PS)
涂层处理 WGA, PEI
检测方法 Radiometric
产品品牌名称 SPA Imaging Beads
运输条件 环境
产品尺寸 500 mg

会员登录

请输入账号

请输入密码

=

请输验证码

收藏该商铺

标签:
保存成功

(空格分隔,最多3个,单个标签最多10个字符)

常用:

提示

您的留言已提交成功!我们将在第一时间回复您~
在线留言

会员登录

请输入账号

请输入密码

=

请输验证码

收藏该商铺

该信息已收藏!
标签:
保存成功

(空格分隔,最多3个,单个标签最多10个字符)

常用:
热线电话 在线询价