simpson228 ,AC/DC Leakage Current Tester,Designed to meet new IEC, ANSI, and UL guidelines
simpson228 ,AC/DC Leakage Current Tester
Test for dangerousleakagecurrentwiththeSimpsonModel228,designed to meet thelatestUL,IEC,andANSIspecifications.The228 detects both ACandDCleakagecurrentandsimulateshumanresponse atthreedifferentlevels--reaction,let-go, andburnhazard. Each Model228comeswithtestleads withalligatorclips,manual, andbatteries.
Simpson 228 Special Purpose AC/DC Milliameter Designed specificallytomeasurehazardous"LeakageCurrents"or"TouchCurrents"which mayappearwhenapersontouchestheconductive surfaceofelectricalorelectronicequipment.The228is designed inaccordancewithIEC,ANSIandULguidelines. • True RMS Readings • Reads in Measurement Indication Units (MIU) up to .005 MIU • Output AllowsMeasurementofPeakCurrentinNon-SinusoidalWaveForms • Let-Go, Reaction, and Burn Hazard Response Networks • Detects dangerous AC & DC Leakage currents • Includes Test Leads, Alligator Clips, Batteries and Manual |
|
Specifications
GENERAL
| Reaction ResponseNetwork | Let-Go ResponseNetwork | UnweightedBurnHazard Response Network | |
Equivalent network component values: | Complies with values specified in IEC 990 (excluding fuse) | |||
Equivalent measuring instrument load: | 1 MΩ- 10pF | 1 MΩ- 62 pF | 1 MΩ- 1 pF | |
Ranges: | 0.3, 1, 3, 10 M.I.U. | 0.3, 1, 3, 10 M.I.U. | 0-100 mA RMS | |
Current accuracy: | ±2% F.S. @ 60 Hz | |||
Meter measurement method: | True RMS | |||
Meter frequency response: | (Relative to ANSI C101-1992 or UL-1459 2nd edition) | |||
DC to 1 Hz | Pointer shall track within 5% of peak | |||
2Hz to 19Hz (Accuracy not supported) |
| |||
20 Hz to 200 KHz | ±2% F.S. | ±2.5% of F.S. | ±2% F.S. | |
200 KHz to 1 MHz | ±2% F.S. | ±2.5% F.S. | ±5% F.S. | |
Output sensitivity: | Full scale meter indication equals 1V RMS (Measured with a 1 MΩ- 12 pF load) | |||
Output accuracy: | ±2% of reading @ 60 Hz | |||
Output frequency response: | (Relative to ANSI C101-1992 or UL-1459 2nd edition) | |||
DC to 50Hz | ±2% of reading | |||
50 Hz to 100 KHz | ±2.5% of reading | ±2% /-3% of reading | ±2% of reading | |
100 kHz to 1 MHz | ±5% of reading | |||
Voltmeter range: | 0-300 V (AC or DC) | |||
Voltmeter accuracy: DC to 1 Hz | Pointer shall track within 5% of peak | |||
2Hz to 19Hz (Accuracy not supported) |
| |||
20 Hz to 1KHz | ±3% F.S. @ 60 Hz (Add ±1% for every additional 100Hz) | |||
Voltmeter frequency response: | DC to 1 KHz | |||
Power requirements: | Power requirements: (2) 9V (NEDA 1604A) batteries | |||
Physical: | 7" x 5.25" x 3.125", 2-1/2 lbs (1.4kg),ABSplastic,fusedinput | |||
Environmental: | 27°C ±2° C, 70% non condensingrelativehumidity.Outsidethisrangederateby10% per °C | |||
Maximum operating range: | 0° to 40° C |
![]() |