正品铜芯铠装高压电缆线-YJV22-2*16电缆的额定电压应适合于电缆系统的运行状况,用U0/U(Um)kv表示。
U0-电缆设计用的导体对地或金属屏蔽之间的额定工频电压;
U-电缆设计用的导体间的额定工频电压;
正品铜芯铠装高压电缆线-YJV22-2*16
电缆额定电压的选择 Voltage designation · 电缆的额定电压应适合于电缆系统的运行状况,用U0/U(Um)kv表示。 U0-电缆设计用的导体对地或金属屏蔽之间的额定工频电压; U-电缆设计用的导体间的额定工频电压; Um-设备可承受的“Z高系统电压"的Z大值。 The rated voltage of the cable for a given applixation shall be suitable for the operating conditions in the system in which the cable is used,and is expressed in the form of U0/U(Um)kv Where: U0-The rated power-frequency voltage between conductors and earth metallic screen ,for which the cable designed; U - The rated power-frequency voltage between conductos, for which the cable designed; Um- The maximum value of the“highest system voltage"for which the equipment may beused. · 三相系统用电缆的U0值推荐如下表: The values of U0 recommened for cable to be used in three-phase systems are listed below:
高压电力电缆专业生产厂家 |
U kv | U m kv | U 0 * kv | A 和 B 类系统 System categories A and B | C 类系统 Systems categories C |
| 6 | 7.2 | 3.6 | 6 |
| 10 | 12 | 6 | 8.7 |
| 15 | 17.5 | 8.7 | 12 |
| 20 | 24 | 12 | 18 |
| 30 | 36 | 18 | - |
| 35 | 40.5 | 21 | 26 |
|
|
A类系统──该类系统任何一相导体与地和接地导体接触时,能在1min内与系统分离 B类系统──该类系统仅包括单相接地故障短时运行的条件,接地故障时间应不超过1h, 但在任何情况下,Z长不超过8h每年接地故障总持续时间不超过125h; C类系统──不属于A类、B类的系统。 System category A──This category comprises those systems in which any phase conductor that comes in contact with earth or an earth conductor. is disconnected from the system within 1 min. System category B ──This category comprises those system which,under faultconditions,are operated,are operated for ashorttimewith one phase earthed.This period should not exceed 1 h..Fora longer period, not exceeding 8h on any occasion, can be tolerated.The total duration of earth faults in any year should not exceed 125h. System categeory C──This category comprises all systems which do not fall into A and B 电缆的型号Type of cable
正品铜芯铠装高压电缆线-YJV22-2*16
|
型号 Type | 名称 Designation | 适用范围 Application | YJV | 铜芯交联聚乙烯绝缘氯乙烯护套电力电缆 Copper conductor,XLPE insulated and PVC sheathed power cable | 室内、隧道及电缆沟等场所,不能承受机械外力。单芯电缆不允许敷设在磁性管道中。 For laying indoors 、 intunnel or cable trench,unable to bear external mechan-icalforces.Single-core cable in magnetic duct is not permissible | YJLY | 铝芯交联聚乙烯绝缘乙烯护套电力电缆 Aluminium conductor, XLPE insulated and PVC sheathed power cable | YJY | 铜芯交联聚乙烯绝缘氯乙烯护套电力电缆 Copper conductor ,XLPE insulated and PEsheathed power cable | YJLY | 铝芯交联聚乙烯绝缘氯乙烯护套电力电缆 Alumimium conductor ,XLPE
|
|
矿用橡套电缆结构特点:
一:导电线芯。柔软性要求以电钻电缆,采掘机电缆为Z高;导线结构采取如下措施:
1, 采用较软的细直径铜单线、以小节距束合、复绞。整根电缆的弯曲扭转性还受到绝缘、护套结构的影响,因此不能认为单丝越细,节距越小越好。
2, 采用同向束绞和复绞可提高柔软性。
3, 为了便于导线在绝缘层中的相对滑动和便于安装维修。电钻电缆和小截面的采掘机电缆导线单丝应镀锡,大截面采掘机电缆在导线外还用包纸带隔离绝缘。
二:绝缘层 要求有足够的电绝缘性能
1, 采用含胶量不低于百分之35的橡皮
2, 绝缘厚度比通用橡套电缆要厚
3, 采用电性好的橡皮,并采用好的挤橡工艺(如挤橡硫化连续生产线)
三:屏蔽层
采用半导电橡皮做屏蔽层,应使其过渡电阻达到标准要求,以保证继电保护系统在事故状态下可靠动作。
四:垫芯
1, 垫芯要充分起到在电缆收到冲砸、挤压时的缓冲作用,又不能过大使外径过大。要求设计合理填满绝缘芯线间的空隙。
2, 机械性能应不低于绝缘橡皮的要求。
3, 不能与绝缘线芯产生粘连。
五:成缆结构
1, 要采用较小的节距倍数,改善电缆的柔软性。
2, 为保证地线芯的机械强度,地线芯截面比通用电缆要大些,小截面产品,采用与主线管相同截面。
3, 控制线芯先单独绞合成组,再与主线芯一起成缆。
六:护层
1, 要求有足够的机械强度,耐磨性好。井下电缆要求阻燃。因此采用氯丁胶,且含胶量不小于百分之五十。
2, 6KV移动橡套电缆要求护套有足够的电绝缘性,改善护套的耐电晕开裂性能。
七:电缆要结构密实、紧凑,各元件有相对滑动性。