产品详情
参数 | DBBSUB | |
单位 | 数据 | |
量程 | kN | 0-0.5, 0-1, 0-2, 0-5 |
受力方式 | 拉力/压力/拉力&压力 | |
灵敏度(RO) | mV/V | 2 ± 0.1% (1±0.2% on 0.5kN capacity) |
压力灵敏度 | %/FS/bar (metre) | <0.05 (<0.005) |
零点平衡 | ±%/Rated Output | 5 |
30分钟蠕变 | ±%/Applied Load | <0.02 |
输出对称性 (张力与压缩) | ±%/Rated Output | <0.1 |
非线性 | ±%/Rated Output | <0.02 |
滞后性 | % / Rated Output | <0.02 |
重复性 | ±%/Rated Output | <0.02 |
温度对零点的影响 | ±%/Rated Output/˚C | <0.002 |
温度对灵敏度的影响 | ±%/Rated Output/˚C | <0.001 |
输入电阻 | Ohms | 1100 ± 50 |
输出电阻 | Ohms | 1000 ± 2 |
绝缘电阻 | Megohms | >5000 @ 100Vdc |
激励电压 | Volts AC or DC | 10 recommended (2-15 acceptable) |
工作温度范围 | ˚C | -40 to +80 (ATEX -40 to +60) |
补偿温度范围 | ˚C | -10 to +40 |
储存温度范围 | ˚C | -40 to +80 |
安全超载 | % of Rated Capacity | 200 |
极限过载 | % of Rated Capacity | 300 |
安全侧负荷 | % of Rated Capacity | 30 |
挠度@额定量程 | mm | 0.3 nominal |
固有响应频率 | Hz | see dimensional table |
IP等级 | IP68 up to 10m water depth/1bar | |
重量(不包括电缆) | kg | 0.55 |
疲劳级 | 108 cycles typical (109 cycles on fatigue-rated version) | |
电缆长度(标准) | metres | 6m |
电缆类型 | Shielded, 4 conductor cable (AWG 24) Ø5mm, Cable jacket polyurethane (PUR) | |
材质 | 17-4 PH Stainless Steel Body. 303 Stainless Steel (Cable Gland) | |
分辨率 | 1/250,000(使用适当的仪器) |