产地 进口 加工定制

Hawke非铠防爆格兰(Hawke 501/421系列 )
Hawke防爆格兰代理商:上海颐品自动化科技有限公司

详细介绍

Hawke非铠防爆格兰(Hawke 501/421系列 )

Hawke非铠防爆格兰密封接头(Hawke 501/421系列 )

Hawke 501 421 Cable Glands

Hazardous Area Cable Glands from Hawke

Hawke防爆格兰(Hawke 501/421 cable glands ) 

Hawke 501/421系列防爆格兰适配非铠装电缆(ATEX,IECEX)

Hawke代理商:上海颐品自动化科技有限公司

Hawke 501/421 cable glands provide a reliable outer cable sheath seal specified to gland and terminate non-armoured elastomer and plastic insulated cables.

Hawke 501/421 cable glands are dual certified Exd and Exe and suitable for installation in Zone 1 (21) and Zone 2 (22) hazardous areas, 3.2-91.6mm outside cable diameters.

When used in increased safety applications the Hawke cable gland can be used to terminate braided cables where the braid and the cable outer sheath enter into the electrical enclosure or junction box.

♦ Exdb IIC Gb, Exeb IIC Gb, Extb IIIC, Db Non-Aromoured Cables ATEX & IECEx Cable Gland

Hawke 501/421 cable gland is suitable for cable termination and installation in Zone 1 (21), Zone 2 (22) and Division 2 hazardous areas.

  • Flameproof Exdb

  • Increased Safety Exeb

  • Dust Extb

  • Dual Certified Cable Gland For Hazardous Areas ATEX – IECEx

HAWKE 501/421 CABLE GLAND TECHNICAL SPECIFICATION

  1. Hazardous Area Cable Gland Classification – Exdb IIC Gb, Exed IIC Gb, Extb IIIC Db

  2. Certificate No’s  – baseefa06ATEX0056X and IECEx BAS 06.0013X

  3. Cable Gland Zone Location – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC

  4. Construction and Test Standards – IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31

  5. Ingress Protection – IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X

  6. Deluge Protection – DTS01

  7. Operating Temperature Range  -60°C to +100°C

CABLE GLAND SELECTION TABLE FOR HAWKE 501/421

HAWKE 501/421 CABLE GLAND SELECTION TABLE
Hawke
Size
 Ref.
Entry Thread SizeThread 
Length
 ‘H’
Cable Acceptance Details‘G’ Compres
sed
 
Length
Hexagon Dimensions
Outer Sheath ‘B’
MetricNPT *Standard SealAlternative (S) SealAcross 
Flats
Across 
Corners
StandardOptionMin.Max.Min.Max.
2KM1615.03.28.023.519.021.2
OsM20 ‡½"15.03.28.023.824.026.5
OM20 ‡½"15.06.511.923.824.026.5
AM20¾"½"15.010.014.39.013.424.830.032.5
BM251″¾"15.013.020.29.515.425.836.039.5
CM321¼"1″15.019.526.515.521.228.246.050.5
C2M401½"1¼"15.025.032.522.028.029.555.060.6
DM502″1½"15.031.544.4/42.3 †27.534.840.465.070.8
EM632½"2″15.042.556.3/54.3 †39.046.538.280.088.0
FM753″2½"15.054.568.2/65.3 †49.558.340.595.0104.0
GM803½"20.067.073.041.0106.4115.0
HM903½"20.067.077.641.0115.0130.0
JM1004″20.075.091.641.0127.0142.0

All dimensions in millimetres (except*).
Os – F size metric entry threads are 1.5mm pitch as standard. For G size Cable Glands and above, a 2mm pitch is supplied as standard (1.5mm pitch with 15mm length of thread can be supplied) please specify when ordering.
† Smaller value is applicable when selecting reduced NPT entry option.
Sizes Os and O are available with an M16 thread size. For O size with an M16 thread, the maximum cable inner sheath diameter is 10.9mm.

CABLE GLAND MATERIAL & FINISH

Hawke 501/421 cable glands are manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard.

PREPARING CABLE & GLAND FOR INSTALLING HAWKE 501/421
CABLE PREPARATION

Allow sufficient length of cable, measurement II, to suit the electrical equipment. If required, install cable gland shroud. Pass cable through the cable gland as shown. If the equipment has a threaded entry, Hawke recommend screwing the cable gland into the equipment to prevent cable twisting after Step B.

CABLE GLAND PREPARATION

Unless already screwed into the electrical equipment, hold the entry (2) in position with a cable gland spanner/wrench to prevent cable rotation and tighten the backnut (1) until resistance is felt between the cable and seal. Then proceed to turn the back nut through a further half to one full turn to complete the inner seal. Locate the shroud over the cable gland where required. To ease wiring inside the equipment strip the cable outer sheath of the cable as shown.

Hawke Cable Glands to view the complete range of hazardous area glands certified according to ATEX & IECEx for Zone 1 / Zone 2.

Flameproof Exdb and Increased Safety Exeb (Dust Extb) Dual Certified glands from Hawke include – for further information review the product pages or contact us to discuss your cable gland requirements.

  • 501/421 Cable Gland Unarmoured   – outer cable sheath cable sealing

  • 501/423 Cable Gland Unarmoured – flameproof seal to inner/outer cable sheath with IP seal on the outer sheath

  • 501/453 Universal Cable Gland Wire Armoured Baided Steel Tape Armoured – indoor/outdoor hazardous areas

  • ICG 623 Barrier Gland Unarmoured – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC hazardous areas

  • ICG 653 Barrier Gland Armoured – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC hazardous areas

      Hawke防爆格兰(Hawke Cable Gland)

Hazardous Area Cable Glands-ATEX IECEX,Exe,Exd Group II

Hawke防爆格兰代理商:上海颐品自动化科技有限公司(4008552521)

关键词:Hawke防爆格兰,Hawke防爆变径,Hawke防爆堵头,Hawke防爆呼吸阀,Hawke防爆接线  盒,Hawke防爆控制箱

Hawke防爆格兰等产品规格书及相关证书-请咨询上海颐品自动化科技有限公司

          上海颐i品代理Hawke非铠防爆格兰密封接头(Hawke 501/421系列  


其他推荐产品更多>>

感兴趣的产品PRODUCTS YOU ARE INTERESTED IN

仪表网 设计制作,未经允许翻录必究 .      Copyright(C) 2021 https://www.ybzhan.cn,All rights reserved.

以上信息由企业自行提供,信息内容的真实性、准确性和合法性由相关企业负责,仪表网对此不承担任何保证责任。 温馨提示:为规避购买风险,建议您在购买产品前务必确认供应商资质及产品质量。

会员登录

×

请输入账号

请输入密码

=

请输验证码

收藏该商铺

登录 后再收藏

提示

您的留言已提交成功!我们将在第一时间回复您~