行业产品

  • 行业产品

上海颐品自动化科技有限公司


当前位置:上海颐品自动化科技有限公司>>Hawke防爆格兰等>>Hawke带胶泥铠装防爆格兰(ICG653/UNIV)

Hawke带胶泥铠装防爆格兰(ICG653/UNIV)

返回列表页

参   考   价: 298.6

订  货  量: ≥100 只

具体成交价以合同协议为准

产品型号Hawke cable gland

品       牌其他品牌

厂商性质代理商

所  在  地上海市

联系方式:张凯文查看联系方式

更新时间:2023-10-31 14:41:20浏览次数:348次

联系我时,请告知来自 仪表网

经营模式:代理商

商铺产品:61条

所在地区:上海上海

联系人:张凯文 (销售经理)

产品简介
产地 进口 加工定制

Hawke带胶泥铠装防爆格兰(ICG653/UNIV)
Hawke防爆格兰代理商:上海颐品自动化科技有限公司

详细介绍

Hawke带胶泥铠装防爆格兰(ICG653/UNIV)

Hawke带胶泥铠装防爆格兰(ICG653/UNIV

Hawke带胶泥铠装防爆格兰(ICG653/UNIV)
Hawke代理商:上海颐品自动化科技有限公司(Hawke cable gland)
Hawke防爆格兰,Hawke防爆密封接头,Hawke防爆堵头,Hawke防爆变径,Hawke防爆呼吸阀,Hawke防爆接线箱
Hawke防爆格兰,Hawke防爆密封接头,Hawke防爆堵头,Hawke防爆变径,Hawke防爆呼吸阀,Hawke防爆接线箱 

HAWKE ICG 653/UNIVERSAL CABLE GLANDS

    

Hawke ICG 653/Universal cable glands are suitable for use with single wire armour ‘W’, wire braid ‘X’ and steel tape armour ‘Z’ elastomer and plastic insulated cables.

For particular use with:-
a) Cable inner sheaths that are not effectively filled, compact and/or circular, have tape bedding or have hygroscopic fillers.
b) Cables that exhibit ‘cold flow’ characteristics.
c) Enclosures containing an ignition source in gas group IIC areas or containing an ignition source in a Zone 1 area.

Hawke ICG 653/Universal cable glands are dual certified Exd and Exe and suitable for installation in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC, 5.5-78.0mm outside cable diameters.

When used in increased safety applications the Hawke cable gland can be used to terminate braided cables where the braid and the cable outer sheath enter into the electrical enclosure or junction box.

♦ Exdb IIC Gb, Exe IIC Gb, Extb IIIC, Db Aromoured Cables ATEX & IECEx Cable Gland.

Hawke ICG 653/Universal cable gland is suitable for cable termination and installation in Zone 1 (21), Zone 2 (22) and Division 2 hazardous areas.

  • Flameproof Exdb

  • Increased Safety Exeb

  • Dust Extb

  • Dual Certified Cable Gland For Hazardous Areas ATEX – IECEx

HAWKE ICG 653/UNIVERSAL CABLE GLAND TECHNICAL SPECIFICATION

  1. Hazardous Area Cable Gland Classification – Exdb IIC Gb, Exeb IIC Gb, Extb IIIC Db

  2. Certificate No’s  – baseefa06ATEX0058X and IECEx BAS 06.0015X

  3. Cable Gland Zone Location – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC

  4. Construction and Test Standards – IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31

  5. Ingress Protection – IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X

  6. Deluge Protection – DTS01

  7. Operating Temperature Range  -60°C to +80°C

CABLE GLAND SELECTION TABLE FOR HAWKE ICG 653/UNIVERSAL

Hawke Size Ref.Entry Thread SizeCable Acceptance Details‘G’ Compressed LengthHexagon Dimensions
Inner Sheath/ Cores‘B’ Outer Sheath‘C’ Armour/Braid
MetricNPT *‘D’ Max. Over Cores‘E’ Max. Inner SheathNOTE 1 Max. No. Of CoresNOTE 2 Max. No. Of CoresAcross FlatsAcross Corners
StandardOptionMin.Max.Orientation 1Orientation 2
OsM20½"8.910.01265.512.00.8 / 1.250 / 0.867.024.026.5
OM20½"8.910.01269.516.00.8 / 1.250 / 0.867.024.026.5
AM20¾"½"11.012.5151012.520.50.8 / 1.250 / 0.867.030.032.5
BM251″¾"16.218.4302116.926.01.25 / 1.60 / 0.773.636.039.5
CM321¼"1″21.924.7424222.033.01.6 / 2.00 / 0.778.046.050.5
C2M401½"1¼"26.329.7606028.041.01.6 / 2.00 / 0.782.455.060.6
DM502″1½"37.141.7808036.052.61.8 / 2.50 / 1.088.765.070.8
EM632½"2″47.853.310010046.065.31.8 / 2.50 / 1.092.780.088.0
FM753″2½"59.066.2/65.3 †12012057.078.01.8 / 2.50 / 1.099.495.0104.0

CABLE GLAND MATERIAL & FINISH

Hawke ICG 653/Universal cable glands are manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard.

PREPARING CABLE & GLAND FOR INSTALLING HAWKE ICG 653/UNIVERSAL
CABLE PREPARATION

Strip Cable to suit equipment as shown above and expose the armour/braid ‘I’ removing all cable fillers.

‘I’ = 20mm for cable gland sizes Os to A ‘I’ = 25mm for cable gland sizes B to C2 ‘I’ = 32mm for cable gland sizes D to F ‘II’ to suit equipment. If required, fit shroud.

CABLE GLAND PREPARATION

Push the cable through the armour spigot (4). Spread armour/braid over the armour spigot (4) until the end of the armour/braid is up against the shoulder of the armour cone. Position the armour clamping ring (3).

Remove the inner seal (5) from the entry (6). Place the entry (6) over the armour spigot (4). Move the sub-assembly (1) and (2) up to meet the entry (6).

Hawke Cable Glands to view the complete range of hazardous area glands certified according to ATEX & IECEx for Zone 1 / Zone 2.

Hawke带胶泥铠装防爆格兰(ICG653/UNIV)
Hawke代理商:上海颐品自动化科技有限公司(Hawke cable gland)
Hawke防爆格兰,Hawke防爆密封接头,Hawke防爆堵头,Hawke防爆变径,Hawke防爆呼吸阀,Hawke防爆接线箱
Hawke防爆格兰,Hawke防爆密封接头,Hawke防爆堵头,Hawke防爆变径,Hawke防爆呼吸阀,Hawke防爆接线箱 


其他推荐产品更多>>

感兴趣的产品PRODUCTS YOU ARE INTERESTED IN

仪表网 设计制作,未经允许翻录必究 .      Copyright(C) 2021 https://www.ybzhan.cn,All rights reserved.

以上信息由企业自行提供,信息内容的真实性、准确性和合法性由相关企业负责,仪表网对此不承担任何保证责任。 温馨提示:为规避购买风险,建议您在购买产品前务必确认供应商资质及产品质量。

会员登录

×

请输入账号

请输入密码

=

请输验证码

收藏该商铺

登录 后再收藏

提示

您的留言已提交成功!我们将在第一时间回复您~