探头

DIL-1

Proven M&C dilution technique

Operation at ambient temperature

Dilution factor from 10:1 to 500:1

With test gas connection

Easy maintenance and operation

Application:

The non-heated M&C dilution unit DIL-1 is used in analysis technique to dilute the sample gas or components in the sample for example in case of toxic gases, moisture measurement or emission measurement. The M&C dilution unit is based on the functional dilution technique which is proved since years in the M&C gas sample probe SP2000-H/DIL.


DIL-1-B

Proven M&C dilution technique

Operation at ambient temperature

Dilution factor from 10:1 to 500:1

With test gas connection

Easy maintenance and operation

Application:

The non-heated M&C dilution unit DIL-1 is used in analysis technique to dilute the sample gas or components in the sample for example in case of toxic gases, moisture measurement or emission measurement. The M&C dilution unit is based on the functional dilution technique which is proved since years in the M&C gas sample probe SP2000-H/DIL.


DIL-1H

Proven M&C dilution technique

Operation at ambient temperature

Optionally heated to 180 or 320°C

Integrated dilution pre-heater

No dew point problems

Dilution factor from 10:1 to 500:1

With test gas connection

Independent of the ambient temperature

Easy maintenance and operation

Application:

The electrically heated M&C dilution unit DIL-1H is used in analysis technique to dilute the sample gas or components in the sample for example in case of toxic gases, moisture measurement or emission measurement. The M&C dilution unit is based on the functional dilution technique which is proved since years in the M&C gas sample probe SP2000-H/DIL.


DIL-1H-B

Proven M&C-dilution technique

Operation at ambient temperature

Optionally heated to 180 or 320°C

Integrated dilution pre-heater

No dew point problems

Dilution factor from 10:1 to 500:1

With test gas connection

Independent of the ambient temperature

Easy maintenance and operation

Application:

The electrically heated M&C dilution unit DIL-1H is used in analysis technique to dilute the sample gas or components in the sample for example in case of toxic gases, moisture measurement or emission measurement. The M&C dilution unit is based on the functional dilution technique which is proved since years in the M&C gas sample probe SP2000-H/DIL.