电缆的额定电压应适合于电缆系统的运行状况,用U0/U
(Um)kV 表示。
U0—电缆设计用的导体对地或金属屏蔽之间的额定工频电
压;
U—电缆设计用的导体间的额定工频电压;电机引接线,交联电缆
Um—设备可承受的“zui高系统电压”的zui大值。
The rated voltage of the cable for a given application shall be suitable for
the operating conditions in the system in which the cable is used,and is
expressed in the form of U0/U(Um)kV. Where:
U0—The rated power-frequency voltage between conductor and earth
or metallic screen,for which the cable designed;
U—The rated power-frequency voltage between conductors,for which
the cable disigned;
Um—The maximum value of the “highest system voltage”for which
the equipment may be used.
U
kV
Um
kV
U0*kV
A 和B 类系统
Syetem categories A and B
C 类系统
Syetem categories C
6 7.2 3.6 6
10 12 6 8.7
15 17.5 8.7 12
20 24 12 18
30 36 18 -
35 40.5 21 26A 类系统—该类系统任何一相导体与地或接地导体接触时,能
在1min 内与系统分离;
B 类系统—该类系统仅包括单相接地故障短路时运行的条件,
接地故障时间应不超过1h,但在任何情况下,zui长不超过8h,
每年接地故障总持续时间不超过125h;
C 类系统—不属于A 类、B 类的系统。
System category A—This category comprises those systems in which any phase
conductor that comes in contact with earth or an earth conductor,is disconnected
from the system
with in 1 min.
System category B—This category comprises those system which,under fault
conditions,are operated for a short time with one phase earthed.This period should
not exceed 1 h.For a longer period,not exceeding 8 h on any occasion,can be
tolerated.The total duration of earth faults in any year should not exceed 125 h.
System category C—This category comprises all syatems which do not fall into
categories A and B.
电缆额定电压的选择Voltage designation
三相系统用电缆的U0 值推荐如下表:The values of U0 recommened for cables to be used in three-phase systems are listed below.
电缆的额定电压应适合于电缆系统的运行状况,用U0/U
(Um)kV 表示。
U0—电缆设计用的导体对地或金属屏蔽之间的额定工频电
压;
U—电缆设计用的导体间的额定工频电压;
Um—设备可承受的“zui高系统电压”的zui大值。
The rated voltage of the cable for a given application shall be suitable for
the operating conditions in the system in which the cable is used,and is
expressed in the form of U0/U(Um)kV. Where:
U0—The rated power-frequency voltage between conductor and earth
or metallic screen,for which the cable designed;
U—The rated power-frequency voltage between conductors,for which
the cable disigned;
Um—The maximum value of the “highest system voltage”for which
the equipment may be used.
U
kV
Um
kV
U0*kV
A 和B 类系统
Syetem categories A and B
C 类系统
Syetem categories C
6 7.2 3.6 6
10 12 6 8.7
15 17.5 8.7 12
20 24 12 18
30 36 18 -
35 40.5 21

免责声明

  • 凡本网注明“来源:仪表网”的所有作品,均为浙江兴旺宝明通网络有限公司-仪表网合法拥有版权或有权使用的作品,未经本网授权不得转载、摘编或利用其它方式使用上述作品。已经本网授权使用作品的,应在授权范围内使用,并注明“来源:仪表网”。违反上述声明者,本网将追究其相关法律责任。
  • 本网转载并注明自其它来源(非仪表网)的作品,目的在于传递更多信息,并不代表本网赞同其观点或和对其真实性负责,不承担此类作品侵权行为的直接责任及连带责任。其他媒体、网站或个人从本网转载时,必须保留本网注明的作品第一来源,并自负版权等法律责任。
  • 如涉及作品内容、版权等问题,请在作品发表之日起一周内与本网联系,否则视为放弃相关权利。
联系我们

客服热线: 15267989561

加盟热线: 15267989561

媒体合作: 0571-87759945

投诉热线: 0571-87759942

关注我们
  • 下载仪表站APP

  • Ybzhan手机版

  • Ybzhan公众号

  • Ybzhan小程序

企业未开通此功能
详询客服 : 0571-87759942