Panametrics Mentor UT for Corrosion
ESA AUTOMATION EW100AA standard HMI
Endress+Hauser Omnigrad M TR10 Modular RTD assembly
Servomex仕富梅气体分析仪
Schenck 申克称重传感器系统
美国泛美Panametrics-NDT 26MG超声波测厚仪
公司介绍主营产品
产品简介在线询价
addition to motors, the SMC Flex controller can be used to control
Description of Features Electronic Motor Overload Protection The SMC Flex controller incorporates, as standard, electronic motor overload protection. This overload protection is accomplished electronically with an I2t algorithm. When coordinated with the proper short-circuit protection, overload protection is intended to protect the motor, motor controller, and power wiring against overheating caused by excessive overcurrent. The SMC Flex controller meets applicable requirements as a motor overload protective device.
The controller’s overload protection is programmable, providing the user with flexibility. The overload trip class consists of either OFF, 10, 15, 20, or 30 protection. The trip current is programmed by entering the motor full-load current rating, service factor, and selecting the trip class.
Thermal memory is included to accurately model motor operating temperature. Ambient temperature insensitivity is inherent in the
electronic design of the overload.
Undervoltage Protection The SMC Flex controller’s undervoltage protection will halt motor operation if a drop in the incoming line voltage is detected. The undervoltage trip level is adjustable as a percentage of the programmed line voltage, from 0…99%. To eliminate nuisance trips, a programmable undervoltage trip delay time of 0…99 seconds can also be programmed. The line voltage must remain below the undervoltage trip level during the programmed delay time.
Overvoltage Protection If a rise in the incoming line voltage is detected, the SMC Flex controller’s overvoltage protection will halt motor operation. The overvoltage trip level is adjustable as a percentage of the programmed line voltage, from 0…199%. To eliminate nuisance trips, a programmable overvoltage trip delay time of 0…99 seconds can also be programmed. The line voltage must remain above the overvoltage trip level during the programmed delay time.
Excessive Starts Per Hour The SMC Flex controller allows the user to program the allowed number of starts per hour (up to 99). This helps eliminate motor stress caused by repeated starting during a short time period. Metering Power monitoring parameters include: 3-phase current Power Factor 3-phase voltage Motor thermal capacity usage Power in kW or mW Elapsed time Power usage in kWH or mWH Note: The motor thermal capacity usage allows the user to monitor the amount of overload thermal capacity usage before the SMC Flex controller’s built-in electronic overload trips. Built-in DPI Communication Capabilities A serial interface port is provided as standard, which allows connection to a Bulletin 20 Human Interface Module and a variety of Bulletin 20-COMM Communication Modules. This includes Allen- Bradley Remote I/O, DeviceNet, ControlNet, Ethernet, ProfiBUS, Interbus, and RS485-DF1. LCD Display The SMC Flex controller’s three-line 16-character backlit LCD display provides parameter identification using clear, informative text. Controller set up can be performed quickly and easily without the use of a reference manual. Parameters are arranged in an organized four-level menu structure for ease of programming and fast access to parameters. Keypad Programming Programming of parameters is accomplished through a five-button keypad on the front of the SMC Flex controller. The five buttons include up and down arrows, an Enter button, a Select button, and an Escape button. The user needs only to enter the correct sequence of keystrokes for programming the SMC Flex controller. Auxiliary Contacts Four fully programmable hard contacts are furnished as standard with the SMC Flex controller: Aux #1, Aux #2, Aux #3, Aux #4 N.O./N.C. Normal/Up-to-Speed/External Bypass/Fault/Alarm/Network Network I/O The SMC Flex can have up to two inputs and four outputs controlled via a communication network. The output contacts use the auxiliary contacts. Ground Fault Input The SMC Flex can monitor for ground fault conditions. An external core balance current transformer is required for this function. See SMC Flex User Manual for additional information. Tach Input A motor tachometer is required for the Linear Speed Start mode. Please see the Specifications section on page 22 for tachometer characteristics. PTC Input A motor PTC input can be monitored by the SMC Flex. In the event of a fault, the SMC Flex will shut down and indicate a motor PTC fault.
For more information, please visit http:///catalogs/
所展示的信息由会员自行提供,内容的真实性、准确性和合法性由发布会员负责,仪表网对此不承担任何责任。仪表网不涉及用户间因交易而产生的法律关系及法律纠纷,纠纷由您自行协商解决
友情提醒 :本网站仅作为用户寻找交易对象,就货物和服务的交易进行协商,以及获取各类与贸易相关的服务信息的平台。为避免产生购买风险,建议您在购买相关产品前务必确认供应商资质及产品质量。过低的价格、夸张的描述、私人银行账户等都有可能是虚假信息,请采购商谨慎对待,谨防欺诈,对于任何付款行为请您慎重抉择!如您遇到欺诈等不诚信行为,请您立即与仪表网联系,如查证属实,仪表网会对该企业商铺做注销处理,但仪表网不对您因此造成的损失承担责任!
相关产品分类更多+
相关技术文章更多+
精彩视频更多+
真菌毒素快速检测仪【呕吐毒素】产品介绍 霍尔德
电力积冰检测传感器是什么?
雨量监测设备寿命多久?
新发产品更多+
德国 ATR VM7
德国 abus TVAC65502
德国 rechner KS-250-M22
HT-Z410 血管支架扭转测试仪 适用标准
血管支架弯曲测试仪 标准解析
CSI-Z410 血管支架扭转测试仪 检测准确
CSI-Z409 血管支架弯曲测试仪 产品参数
指示灯A-01BM日本开关NKK
仪表网-仪器仪表行业“互联网+”服务平台
Copyright ybzhan.cn All Rights Reserved法律顾问:浙江天册律师事务所 贾熙明律师ICP备案号:浙B2-20100369-24
客服热线:0571-87756399,87759942加盟热线:0571-87756399展会合作:0571-87759945客服邮箱:873582202@qq.com 投稿邮箱:ybzhan@qq.com
网站客服:QQ:873582202服务咨询:QQ:568547636对外合作:QQ:531350588仪表采购群: 仪表技术群:版权所有©浙江兴旺宝明通网络有限公司
版权所有©浙江兴旺宝明通网络有限公司
在线客户服务扫二维码加微信
*
*您想获取产品的资料:
个人信息:
会员登录新用户注册 >
请输入账号
请输入密码
请输验证码
联系方式
深圳市大成机电技术有限公司
采购或询价产品,请直接拨打电话联系
联系人: